TALENT ELECTRIC SERVICES LLC
Enhancing Electrosafety Solutions.
Oman’s Own New Generation
‘Plug on’ DBs
Proudly manufactured in Oman by:
AL SALAMAH
DB construction: Fabricated material are made from Electro- galvanized
steel / Galvanized steel sheet. (1.2mm Thickness).
Painting: All parts are pretreated and powder coated with polyester
powder electro statically.
Powder shade : RAL 7032/ 7035, polyester powder coated textured
finish, light grey.
Degree of protection : IP42.
Door lock : Durable plastic material slide latch type.
Customized options available
AL SALAMAH
ةمسلا
2
Al Salamah Distribution Boards are designed and manufactured in Oman by Talent
Electric Services LLC. The DB assembly has been exclusively designed for
Schneider Electric’s new generation plug on type breakers which offer operational
ease compared to traditional bolt on type beakers. The breakers come with a special
trip indicator that helps in distinguishing the trip from a manual shut down. The
enclosures for the DB assembly are manufactured in Talent’s state of the art factory
housing high end computer aided design facilities, high precision CNC machinery and
powder coating facility. The DBs are available in surface and flush type designs and in
specifications ranging from 4 way to 16 way in both single phase and three phase.
Distribution Board Specification
SINGLE PHASE DB
Plug-on pan assembly type
3
Dimensions - All are in MMDimensions - All are in MM
4 WAYS
8 WAYS
12 WAYS
16 WAYS
TOP/ BOTTOM VIEW
W 2
H 1
H 2
12 WAYS
16 WAYS
370365220 225
445
440220 225
520515220 225
295285220 230
W 1
110
SIDE VIEW
PUSH
375365220
450440220
525515220
230
230
230
S1P04W F
S1P08W F
S1P12W F
S1P16W F
110
FRONT VIEW WITH DOOR
S
XX
X
16W : 16 Ways
1P
1P: Single Phase
F : Flush type
S : Surface type
Standard Configurations
Configuration of Single Phase DB's and definition of references
Ordering Reference Guide
S1P
04W
S
Reference for Single Phase DB
S1P = Al Salamah Single Phase
Reference for number of ways
04W = 4 Ways
Reference for mounting type
S = Surface type
F = Flush type
ORDERING
REFERENCE
NUMBER
FLUSH
H2 W2
TYPE H1 W1
Flush Type Single Phase DB
ORDERING
REFERENCE
NUMBER
SURFACE
H2 W2
S1P04W S
290
TYPE
4 WAYS
8 WAYS
H1 W1
285220
S1P08W S
S1P12W S
S1P16W S
225
Surface Type Single Phase DB
ORDERING REFERENCE :-
Number of Ways
08W : 8 Ways
12W : 12 Ways
S : Al Salamah
(Talent Brand)
04W : 4 Ways
AL SALAMAH
ةمسلا
THREE PHASE DB
Plug-on pan assembly type
4
Number of Ways
18W : 18 Ways
24W : 24 Ways
30W : 30 Ways
36W : 36 Ways
12W : 12 Ways
42W : 42 Ways
48W : 48 Ways
04 WAYS
06 WAYS
08 WAYS
10 WAYS
12 WAYS
14 WAYS
16 WAYS
S3P18W S
S3P24W S
S3P30W S
S3P36W S
S3P42W S
S3P48W S
385380500 505
385380560 565
385380620 625
385380680 685
385380740 745
385380800 805
S3P12W F
390380440 450
S3P18W F
PUSH
S3P24W F
S3P30W F
S3P36W F
S3P42W F
S3P48W F
380500 510
380560 570
380620 630
380680 690
380740 750
380800 810
390
390
390
390
390
390
Dimensions - All are in MM
Dimensions - All are in MM
H 1
120
SIDE VIEWFRONT VIEW WITH DOOR
TOP/ BOTTOM VIEW
H 2
W 2
W 1
120
ORDERING
REFERENCE
NUMBER
FLUSH
H2 W2
TYPE
H1 W1
Flush Type Three Phase DB
ORDERING
REFERENCE
NUMBER
SURFACE
H2 W2
S3P12W S
385
TYPE H1 W1
380440 445
Surface Type Three Phase DB
ORDERING REFERENCE :-
S : Al Salamah
(Talent Brand)
S
XX
X
3P
3P: Three Phase
F : Flush type
S : Surface type
Standard Configurations
Configuration of Three Phase DB's and definition of references
Ordering Reference Guide
S3P
12W
S
Reference for Three Phase DB
S3P = Al Salamah Three Phase
Reference for number of ways
12W = 12 Ways
Reference for mounting type
S = Surface type
F = Flush type
04 WAYS
06 WAYS
08 WAYS
10 WAYS
12 WAYS
14 WAYS
16 WAYS
AL SALAMAH
ةمسلا
Row Distribution Board Surface Type
6
Standard Configurations
Configuration of Row DB's and definition of references
Ordering Reference Guide
TRDB
4
S
16
Reference for Row DB
TRDB = Talent Row DB
Reference for number of rows
4 = 4 Row DB
Reference for mounting type
S = Surface type
Reference for number of module
16 = 16 Module single pole MCB
24 = 24 Module single pole MCB
W 2
H 2
150(TYP.)
290 - 16M
434 - 24M
H 1
115
SIDE VIEW
PUSH
ORDERING
REFERENCE
NUMBER
SURFACE
H2 W2
TRDB1S24
597
TYPE
1 ROW
2 ROW
3 ROW
4 ROW
5 ROW
6 ROW
H1 W1
585300
450
600
750
900
1050
TRDB2S24
TRDB3S24
TRDB4S24
TRDB5S24
TRDB6S24
Surface Type Row DB 24M
ORDERING
REFERENCE
NUMBER
SURFACE
H2 W2
TRDB1S16
452
TYPE
1 ROW
2 ROW
3 ROW
4 ROW
5 ROW
6 ROW
H1 W1
440300
450
600
750
900
1050
TRDB2S16
TRDB3S16
TRDB4S16
TRDB5S16
TRDB6S16
312
462
612
762
912
1062
312
462
612
762
912
1062
440
440
440
440
440
452
452
452
452
452
Surface Type Row DB 16M
597585
597585
597585
597585
597585
Number of Rows
2 : 2 Rows
3 : 3 Rows
4 : 4 Rows
5 : 5 Rows
T : Talent Electric Services LLC
1 : 1 Row
T
X
X
6 : 6 Rows
RDB
RDB: Row Distribution Board
XX
16 Modules in each row
24 Modules in each row
F : Flush type
S : Surface type
W 1
FRONT VIEW WITH DOOR
TOP/ BOTTOM VIEW
Dimensions - All are in MM
Dimensions - All are in MM
115
AL SALAMAH
ةمسلا
Row Distribution Board Flush Type
7
FRONT VIEW WITH DOOR
H 2
290 - 16M
434 - 24M
W 1
TOP/ BOTTOM VIEW
W 2
115
TYPE
1 ROW
2 ROW
3 ROW
4 ROW
5 ROW
6 ROW
H1 W1
585300
450
600
750
900
1050
TRDB2F24
TRDB3F24
TRDB4F24
TRDB5F24
TRDB6F24
320
470
620
770
920
1070
Flush Type Row DB 24M
ORDERING
REFERENCE
NUMBER
FLUSH
H2 W2
TRDB1F16
460
TYPE
1 ROW
2 ROW
3 ROW
4 ROW
5 ROW
6 ROW
H1 W1
440300
450
600
750
900
1050
TRDB2F16
TRDB3F16
TRDB4F16
TRDB5F16
TRDB6F16
320
150(TYP.)
Number of Rows
2 : 2 Rows
3 : 3 Rows
4 : 4 Rows
5 : 5 Rows
T : Talent Electric Services LLC
1 : 1 Row
T
X
X
6 : 6 Rows
RDB
RDB: Row Distribution Board
XX
16 Modules in each row
24 Modules in each row
F : Flush type
S : Surface type
Standard Configurations
Configuration of Row DB's and definition of references
Ordering Reference Guide
TRDB
4
F
16
Reference for Row DB
TRDB = Talent Row DB
Reference for number of rows
4 = 4 Row DB
Reference for mounting type
F = Flush type
Reference for number of module
16 = 16 Module single pole MCB
24 = 24 Module single pole MCB
605
460
605
460
605
460
605
460
605
460
470
620
770
920
1070
440
440
440
440
440
Flush Type Row DB 16M
585
585
585
585
585
H 1
115
SIDE VIEW
PUSH
ORDERING
REFERENCE
NUMBER
FLUSH
H2 W2
TRDB1F24
605
Dimensions - All are in MM
Dimensions - All are in MM
AL SALAMAH
ةمسلا
Plug-On
Installation type
Devices
Easy to install, convenient,
fast and safety
Finger proof IP2X
busbar
Positive contact
indication
Test button, on the
front panel
Fault tripping is indicated by a red
mechanical indicator on the front
face
5
Plug-on type Pan Assembly and Circuit Breakers Overview